4 Ton Quad Zone Mini Ductless Split Air Conditioner 51000 BTU48,000 BTU Ductless Mini Split AC
21 SEER Efficiency w/ Heat Pump Technology
With a 48000 BTU total Cooling-Heating Capacity, this Inverter DC mini split
system can cool or heat 4 seperate 9000-12000-12000-18000 BTU zones [400 + 400 + 600 + 900 ft²] for a total coverage area of 2500 ft². A 21 SEER rating coupled with Inverter technology provides the benefits of low operation temps, rapid cooling as well as maximum energy efficiency. Includes LCD remote-warranty package. Linesets and wire sold seperately.
System
Features
Specifications
Installation Kit
Setup - Installation
Warranty
Shipping
Technical Data:
System Includes:
51000 BTU Cooling Capacity:
(9k + 12k + 12k + 18k)
51000 BTU Heat Pump Capacity:
(9k + 12k + 12k + 18k)
INVERTER DC TECHNOLOGY:
21 SEER
Quad-Zone Setup
(4 Air Handlers)
1 Year Parts - 5 Year Compressor Warranty
View Details >
Indoor Units - Air Handler
[x 4]
Outdoor Compressor w/ Total Rating of 48,000 BTU's
Digital, Multi-function LCD Remote Control
[x 4]
Filtration Screens - Multi Folds Evaporator
*When all four air handlers are running simultaneously at full capacity,
the total combined BTU output is limited to that of the outdoor condenser.
Top Line Features:
Quad Air Handlers
for Multi-Zone Placement
INVERTER DC TECHNOLOGY:
21 SEER
Intelligent Mechanical Defrosting
Washable Filters - Biologically Actv Enzyme
Low Startup Temps - MAXIMUM EFFICIENCY
Pre-charged with freon for 100ft of piping
Sleep Mode - 24 hour ON/OFF Timer - Memories
Enhanced Copper Coil - Wide Angle Air Spread
2500 ft² coverage area: 400 + 600 + 600 + 900
** Installation Lineset Sold Seperately: Available in 15-75ft Lengths.
Contact us
for customized package or
Click here
to Purchase.
9000 BTU Indoor Air Handler Specs:
CLICK TO ENLARGE
12000 BTU Indoor Air Handler Specs:
CLICK TO ENLARGE
18000 BTU Indoor Air Handler Specs:
CLICK TO ENLARGE
Outdoor Compressor Unit Specs:
CLICK TO ENLARGE
WHAT IS DC INVERTER?
DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. As known, the current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result different running speeds of the compressor. YMGI Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter air conditioners bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Contioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.
Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling or heating to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly. Once the set temperature is reached, it slows down and adjust its capacity to counter the heat loss or heat gain of the building. By this way it will maintain a constant temperature.
BASIC OVERVIEW:
The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and the condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with Freon however, the lines still need to be vacuumed to evacuate the excess Nitrogen prior to the final coupling for operation. Although the installation may seem easy to some, certain tools and experience is necessary to complete installation of a mini split*
See Installation Tip
. A certified HVAC technician must conduct / complete the installation to be eligible for the warranty.
(See warranty details below > )
*5 Year Compressor - 1 Year on all other Parts*
Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and brand new exchange will be shipped out.
Download Manual - Warranty Polices >
These Mini Split units usually ship via
SAIA Motor Freight
(on truck) or some other freight service. These units ship out of Missouri and are in transit with 2 business days from payment receipt. Depending on where you are geographically located, transit time is usually between 3 and 6 business days. Please provide a contact phone# upon checkout where recipient of order can be reached. SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Only ships to the lower 48 Contiguous United States.
Condenser Ground Stand
- Provides Flat even surface
- Avoids debris obstruction
Price:
.00
Click for more Info
Lineset (1/4 x 3/8)
- Required for Installation
15ft > 75ft Length Options
Price:
.00 > 4.00
Click for more Info
Condenser Bracket
- Mount your condenser at any height on an outdoor sidewall
Price:
.00
Click for more Info
Micro-Pump II
- Required when mounting air handler on Interior wall
Price:
2.00
Click for more Info
Electrical Wire Harness
- 16/4 Electrical Wire Harness
- For Extending Evap. Length
Price:
.75 / ft
Click for more Info
Additional Remote Controls
- Spare remote controls for the T1 Series Ductless System
Price:
.00
Click for more Info
Lineset Covers
- Available in different sizes
- Concels and protects linesets
Price:
.00 - .00
Click for more Info
Programmable Thermostat
- Permanently Hard Mounts
- Programs 7 days a week
Price:
2.00
Click for more Info
Swap 1 - 9k Wall Mount for Ceiling Cassette:
(+) 0 *
Swap 1 - 12k Wall Mount for Ceiling Cassette:
(+) 0
Swap 1 - 18k Wall Mount for Ceiling Cassettes:
(+) 5
Swap all 4 Wall Mounts for Ceiling Cassettes:
(+) 5
* No 9000 BTU cassettes - need to exchange for 12000 BTU
Swap 1 - 9k Wall Mount for Susp. Ceiling Mount:
(+) 0
Swap 1 - 12k Wall Mount for Susp. Ceiling Mount:
(+) 2
Swap 1 - 18k Wall Mount for Susp. Ceiling Mount:
(+) 8
Swap all Wall Mounts for Susp. Ceiling Mounts:
(+) 2
*If alternate air handler types are preferred, request invoice with preferred options upon checkout or
contact us.